Capable of managing two sets of batteries, this sensor allows you to continuously monitor the state of your batteries and to optimise your consumptions and charge time; an NKE exclusivity.
Also available in a 200A version.
Electrical Characteristics
Maximum current carrying capacity:
• 40A on a permanent basis
• 100A for 2 minutes
• 200A for 30 seconds
• Type of fuse protecting the measurement wire plus: 5 x 20 100mA
• Power consumption: 0.3 mA
Mechanical Characteristics
• Overall height with lug: 60mm
• Length: 105mm, Width: 71mm
• Drilling diameter for mounting holes: 5mm
• Centre-to-centre drilling distance for mounting screws: 95mm
• Weight: 700 g
• Nut type for stud bat1, bat2 and COM: M10
Note: You can connect a set of batterie in 12V and the second one in 24V
Part Number: 90-60-020
|